Sealey SA50 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug Sealey SA50 herunter. Sealey SA50 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these
instructions and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
WARNING! Ensure health & safety, local authority, and general workshop practice regulations are adhered
to when using this equipment.
WARNING! Disconnect from air supply before changing accessories or servicing.
Maintain the needle scaler in good condition and replace any damaged or worn parts. Use genuine parts
only. Unauthorised parts may be dangerous and will invalidate the warranty.
WARNING! Check correct air pressure is maintained and not exceeded. We recommend 90psi.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use and ensure
that all connections are secure.
Only use needles which are specifically designed for use with a needle scaler.
Wear approved safety eye/face shield, ear defenders, and hand protection.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
Keep children and non-essential persons away from the working area.
DO NOT use the needle scaler for a task it is not designed to perform.
WARNING! DO NOT use needle scaler if damaged or thought to be faulty. (Contact Sealey service agent).
DO NOT use needle scaler unless you have been instructed in its use by a qualified person.
DO NOT carry the needle scaler by the air hose, or yank the hose from the air supply.
DO NOT operate needle scaler if you are tired or under the influence of alcohol, drugs or intoxicating
medication.
DO NOT carry needle scaler with your hand on the power trigger in order to avoid unintentional starting.
DO NOT direct air from the air hose at yourself or others.
When not in use disconnect from air supply and store in a safe, dry, childproof location.
INSTRUCTIONS FOR:
AIR NEEDLE SCALER
MODEL No: SA50.V2
2. INTRODUCTION & SPECIFICATIONS
Pistol type scaler suitable for cleaning heavy paint and rust scale from metal surfaces. Removable needle head
allows use as a standard air hammer but requires additional chisel set and spring retainer (not included).
Features variable speed trigger control. Replacement needle sets available.
Stroke: ...................................35mm
Free speed: ............................4800bpm
Air consumption:.............................7cfm
Operating pressure: .........................90psi
Air inlet size:.............................1/4”BSP
Weight: ...................................2.1kg
Noise Power: ...........................113dB(A)
Noise Pressure: .........................102dB(A)
Vibration Emission Value:...................11.6m/s²
Uncertainty Emission Value:.................1.64m/s²
Replacement Needle Set (19pc): .............SA50.02
Optional Chisel Sets: ...........AK50(5pc), AK57(7pc)
Spring Retainer: ........................ SA11R/17
Original Language Version
SA50.V2 Issue: 2(SP) - 26/11/13
© Jack Sealey Limited
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - SA50.V2

Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and properly mai

Seite 2 - 4. OPERATING INSTRUCTIONS

3.1. Assembly3.1.1. Screw the scaling head fully onto the body as indicated above in fig.1.3.1.2. Tighten the 3 grub screws located around the scali

Seite 3 - 5. MAINTENANCE

 WARNING! Disconnect needle scaler from air supply before changing accessories, servicing or performing maintenance. Replace or repair damaged p

Seite 4

WARNING! – Risk of Hand Arm Vibration Injury.This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.This tool is subject

Verwandte Modelle: SA661 | SA660 |

Kommentare zu diesen Handbüchern

Keine Kommentare