Sealey VS402 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Für das Auto Sealey VS402 herunter. Sealey VS402 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
 Keep this product in good working order and condition, take immediate action to repair or replace damaged parts.
 Use approved parts only. Unapproved parts will invalidate the warranty.
 Keep children and unauthorised persons away from the work area.
 Keep work area clean and tidy and free from unrelated materials.
 Ensure the work area has adequate lighting.
 DO NOT use the kit to perform a task for which it is not designed.
 DO NOT hold pump inlet against the skin whilst using the pump.
 DO NOT allow untrained persons to use the kit.
 DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.
 After use, clean equipment and store in a cool, dry, childproof area.
 WARNING!Brake fluid will damage paintwork. Any spillage should be flushed with water immediately.
 WARNING!Brake fluid is flammable - keep away from sources of ignition, including hot surfaces e.g. exhaust manifold.
Dispose of waste liquids in accordance with local authority regulations.
 WARNING! DO NOT pollute the environment by allowing uncontrolled discharge of fluids.
Always read and comply with the warnings on the brake fluid container.
Wear eye protection and keep skin contact to a minimum. If brake fluid enters eyes rinse with plenty of water and seek medical advice. If swallowed seek
medical advice immediately.
The VS402.V2 vacuum tester and brake bleeding kit is a multi-function diagnostic tool used to test a variety of essential engine and associated functions including
fuel, ignition, transmission and emissions. Set also includes reservoir, hoses and adaptors for bleeding brake and clutch systems on cars, commercials and
motorcycles. Brass-bodied vacuum pump features large, easy-to-read vacuum gauge calibrated in both inches and millimetres of mercury.
1. SAFETY INSTRUCTIONS
2. SPECIFICATION & CONTENTS
INSTRUCTIONS FOR:
VACUUM TESTER AND
BRAKE BLEEDING KIT
MODEL No
.
VS402.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years
of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
Original Language Version
VS402.V2 Issue: 1 - 22/05/12
© Jack Sealey Limited
ITEM PART No. DESCRIPTION ITEM PART No. DESCRIPTION
1 VS402.V2-01 VACUUM PUMP WITH GAUGE 6 VS402.V2-06 HOSE ADAPTOR
2A VS402.V2-02A RESERVOIR LID (FOR OPERATION) 7 VS402.V2-07 HOSE ADAPTOR 'T-PIECE'
2B VS402.V2-02B RESERVOIR LID (FOR TRANSPORT) 8 VS402.V2-08 HOSE ADAPTOR 'STRAIGHT'
3 VS402.V2-03 RESERVOIR JAR 9 VS402.V2-09 BRAKE BLEED NIPPLE ADAPTOR
4 VS402.V2-04 560mm VACUUM HOSE 10 VS402.V2-10 UNIVERSAL CUP ADAPTOR
5 VS402.V2-05 80mm VACUUM HOSE
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - VS402.V2

 Keep this product in good working order and condition, take immediate action to repair or replace damaged parts. Use approved parts only. Unappro

Seite 2 - 3. INTRODUCTION

The use of a vacuum gauge is often overlooked when determining mechanical condition and carrying out fault diagnosis on internal combustion engines. M

Seite 3 - 5. FUEL SYSTEMS

4.3. Ignition System Vacuum Advance4.3.1. On standard points systems and some electronic ignition systems there are two types of advance methods used

Seite 4 - Original Language Version

6.1. Testing One-Way Valves6.1.1. Many vacuum operated circuits use in-line one-way valves to apply vacuum in one direction only. 6.1.2. To test the

Seite 5 - 7. BRAKING SYSTEMS

fig.10fig.11fig.12fig.13 7. BRAKING SYSTEMS7.1. Testing Brake Servo Diaphragm7.1.1. Remove vacuum supply line from brake servo fitting. Attach VS40

Seite 6 - 01284 757500

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prio

Verwandte Modelle: VS4021