Figure 5.15
4) Use the ESC button to return to previous menu.
Recording Data
The Record Data function allows recording vehicle modules
Parameter Identification (PID) data to help diagnose
intermittent vehicle problems. You could save data files to the
SD card and then use the Playback function to view the saved
files.
NOTE: The length of time for each frame varies per vehicle.
Generally, one frame of data is about 1/4 second, or 4 frames per
second.
1) To record live data, with the live data screen displaying, select
Save on the bottom. The scan tool will start timing to record
retrieved live data and PID graphs.
If you record live data under text mode, following screen
shows:
Figure 5.16
Custom List
Numbers of DTCs
0
Fuel system 1 status
OL
Pause Graphics Save
Complete List
Numbers of DTCs
0
Fuel system 1 status
OL
Fuel system 2 status
--
Calculated load value
0.0
%
Engine coolant
temperature
-40
0
C
Pause Graphics Saving 94
Seitenansicht 30